Crude Storage Tank Roof Corrosion Coating
Corroded crude tank roof and shell blasted, rebuilt cold, and barrier-coated to stop further atmospheric loss.
What was failing
A crude storage tank roof and shell lose wall to atmospheric corrosion. Rain, dew, and standing water sit on the roof plates and run down the shell, and the steel rusts and thins from the outside in. As the metal is lost, pitting opens up and the protective surface breaks down, so the corrosion runs faster the longer it is left. Eventually the thinning threatens the integrity of the roof and the upper shell, and the owner faces plate replacement and a tank pulled from service.

How AAS approaches it
We start by blasting the roof and shell back to clean, profiled steel so the corrosion product is gone and the repair has a sound surface to bond to. We rebuild the pitted and thinned areas cold with Belzona 1000 Series composites, bringing the steel back to profile with no hot work on a tank that holds crude. Then we apply a Belzona 5000 Series barrier coating over the roof and shell to separate the steel from the weather and stop further atmospheric loss. We work the surfaces in stages so water cannot get back under the coating before it cures.
Assess and map
We inspect the roof and shell to locate pitting and metal loss and confirm the areas that need rebuilding before coating.
Blast to clean steel
We abrasive blast the roof and shell to a clean, profiled surface so the corrosion product is removed and the repair bonds to bare steel.
Rebuild thinned areas
We rebuild pitted and thinned steel cold with 1000 Series composites, with no hot work on a tank in crude service.
Apply barrier coating
We apply a 5000 Series barrier coating over the roof and shell as one continuous film that separates the steel from the weather.
Cure and return to service
We confirm the coating is cured and continuous, then hand the tank back to the owner ready for service.
The result
From the job
Repair and protection work of this kind, performed by AAS crews across Louisiana.
Capabilities used here
Where this work happens
Other projects

Storage Tank Floor Reclamation
Corroded aboveground tank floor rebuilt and lined back to immersion service without cutting out plate.
View project
Centrifugal Pump Rebuild & Efficiency Restoration
Cold-rebuilding an eroded pump casing and lining it to restore clearances, no new casting required.
View project
Live Pipe Leak Seal & Composite Wrap
Live leak sealed and a degraded process line reinforced with an engineered composite wrap, no welding and often no shutdown.
View project
Wastewater Clarifier & Concrete Structure Relining
Spalled, rebar-exposed concrete clarifier rebuilt and relined for continued immersion service.
View project
Heat Exchanger Water Box Protection
Blasting, metal rebuild, and a barrier coating restore a corroded exchanger water box and tube sheet in cooling-water service.
View projectHave equipment that needs to stay in service?
Tell us what is failing. We respond quickly, and we offer 24-hour on-call service.