Potable Water Standpipe and Riser Lining
Corroding standpipe and riser rebuilt and lined for potable water service without cutting and replacing plate.
What was failing
A potable water standpipe and its riser carry treated drinking water, so the inside steel has to stay clean and intact. Over time the wetted steel corrodes, and pitting concentrates at the floor and along the weld seams where water sits and stress is highest. That corrosion does two things at once. It puts rust into the water that has to stay clean, and it thins the wall that holds the column of water. Left alone, the pitting deepens, the seams keep losing metal, and the asset moves toward a release and an outage on a system that cannot simply be shut off.

How AAS approaches it
We take the internals back to bare, sound steel before anything else goes on. We grit-blast the wetted surfaces to a clean, profiled finish so the repair and the lining bond to metal, not to old corrosion. We rebuild the pitted floor and the weld seams with a Belzona 1000 Series composite, bringing the lost profile back so the lining has continuous steel to sit on. Then we apply a lining suited for potable water service across the wetted steel, so the rebuilt floor and seams and the surrounding wall all sit under one continuous barrier. The water stays clean and the corrosion is held back, all without cutting and replacing plate.
Assess the wetted steel
We inspect the standpipe and riser internals to map the pitting at the floor and weld seams and to confirm the surfaces that need rebuilding and lining.
Grit-blast prep
We grit-blast the wetted steel to a clean, profiled surface so both the composite and the potable-water lining bond to bare metal.
Rebuild floor and seams
We rebuild the pitted floor and the weld seams with a Belzona 1000 Series composite, restoring lost profile with no plate replacement.
Apply potable water lining
We apply a lining suited for potable water service over the wetted steel so the rebuilt areas and the wall sit under one continuous barrier.
Inspect and return to service
We check the lining and the rebuilt areas and hand the standpipe and riser back ready for potable water duty.
The result
From the job
Repair and protection work of this kind, performed by AAS crews across Louisiana.
Capabilities used here
Where this work happens
Other projects

Storage Tank Floor Reclamation
Corroded aboveground tank floor rebuilt and lined back to immersion service without cutting out plate.
View project
Centrifugal Pump Rebuild & Efficiency Restoration
Cold-rebuilding an eroded pump casing and lining it to restore clearances, no new casting required.
View project
Live Pipe Leak Seal & Composite Wrap
Live leak sealed and a degraded process line reinforced with an engineered composite wrap, no welding and often no shutdown.
View project
Wastewater Clarifier & Concrete Structure Relining
Spalled, rebar-exposed concrete clarifier rebuilt and relined for continued immersion service.
View project
Heat Exchanger Water Box Protection
Blasting, metal rebuild, and a barrier coating restore a corroded exchanger water box and tube sheet in cooling-water service.
View projectHave equipment that needs to stay in service?
Tell us what is failing. We respond quickly, and we offer 24-hour on-call service.